Aluminum Conductor PVC / XLPE Insulated Steel Wire Armoured Power Cable
US$0.89 | 1,000 Meters (MOQ) |
Production Capacity:
100, 000.00 a Week
Transport Package:
Wooden Exported Drum, Flexible Package,
Payment Terms:
L/C, T/T
Henan Hengtian Special Cable Co., Ltd.
Henan, China
Last Login Date:
Jul 20, 2018
Business Type:
Manufacturer/Factory
Main Products:
Power Cable, Electric Cable, Electrical Cable, Building Wire, ABC Cable, ACSR, Elevator Cable, Rubber Cable, Special Cable
Find Similar Products
Product Description
Company Info
Basic Info.
Model NO.
YJLV
Application
Construction, Underground, Industrial, Power Station
Voltage
Low and Medium Voltage Cable
Current
Insulation Material
XLPE
Sheath Material
Material Shape
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, CE
Model
YJLV22
Brand
Hengtian
1
Fire Retardant
2
Flame Retardant
Trademark
Hengtian
Specification
IEC
Origin
Henan, China
HS Code
85444921
Product Description
Aluminum Conductor PVC / XLPE Insulated Steel Wire Armoured Power Cable
1) Standard: IEC60502, GB/T 12706
2). Voltage: 0.6/1KV
Conductor:
Solid or stranded Copper/Aluminum
-Insulation:
Cross-linked polyethylene( XLPE or PVC)
-Filler:
Polypropylene lament with lapped binding tape
-Inner Sheath:
Polyvinyl chloride (Black)
-Armor:
Galvanized steel wire/steel tape/Unarmored/Aluminum wire
-Core-covering:
Binding tape
-Outer Sheath:
Polyvinyl chloride (Black)
3). Operating characteristics:
Rated power-frequency voltage u0/u: 0.6/1 KV
Max permissible continuous operating temperature of conductor 70
Max short-circuit temperature of the conductor shall not exceed (Max 5 seconds duration): Cross-section of conductor 300 mm2
The anbient temperature under installations should not be below 0
The bending radius of single core cable should not be less than 20 times of the cable diameter, the bending radius of multi-core cable should not be less than 15 times of the cable diameter
4)Application:
1, For laying indoors, in tunnel or cable trench, unable to bear extermal mechanical forces. Single core cable is not permissible to lay in magnetic duct.
2, For laying indoors, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear pulling force.
5) Four core electrical power cable specification
Cable size
(sq.mm)
Conductor type
Nominal thickness of PVC insulation(mm)
Nominal thickness of PVC sheath(mm)
Approx. cable overall diameter (mm)
Max. D.C resistance @ 20ºC (Ω/km)
4x1.5
RE or RM
0.8
1.8
11.0
12.1
4x2.5
RE or RM
0.8
1.8
11.9
7.41
4x4
RE or RM
1.0
1.8
14.0
4.61
4x6
RE or RM
1.0
1.8
15.3
3.08
4x10
RM
1.0
1.8
18.4
1.83
4x16
RM
1.0
1.8
20.9
1.15
4x25
SM
1.2
1.8
21.9
0.727
4x35
SM
1.2
1.8
24.1
0.524
4x50
SM
1.4
1.9
27.6
0.387
4x70
SM
1.4
2.1
31.4
0.268
4x95
SM
1.6
2.2
36.1
0.193
4x120
SM
1.6
2.3
39.3
0.153
4x150
SM
1.8
2.5
43.5
0.124
4x185
SM
2.0
2.7
48.4
0.0991
4x240
SM
2.2
2.9
54.6
0.0754
4x300
SM
2.4
3.1
60.4
0.0601
1) Standard: IEC60502, GB/T 12706
2). Voltage: 0.6/1KV
Conductor:
Solid or stranded Copper/Aluminum
-Insulation:
Cross-linked polyethylene( XLPE or PVC)
-Filler:
Polypropylene lament with lapped binding tape
-Inner Sheath:
Polyvinyl chloride (Black)
-Armor:
Galvanized steel wire/steel tape/Unarmored/Aluminum wire
-Core-covering:
Binding tape
-Outer Sheath:
Polyvinyl chloride (Black)
3). Operating characteristics:
Rated power-frequency voltage u0/u: 0.6/1 KV
Max permissible continuous operating temperature of conductor 70
Max short-circuit temperature of the conductor shall not exceed (Max 5 seconds duration): Cross-section of conductor 300 mm2
The anbient temperature under installations should not be below 0
The bending radius of single core cable should not be less than 20 times of the cable diameter, the bending radius of multi-core cable should not be less than 15 times of the cable diameter
4)Application:
1, For laying indoors, in tunnel or cable trench, unable to bear extermal mechanical forces. Single core cable is not permissible to lay in magnetic duct.
2, For laying indoors, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear pulling force.
5) Four core electrical power cable specification
Cable size
(sq.mm)
Conductor type
Nominal thickness of PVC insulation(mm)
Nominal thickness of PVC sheath(mm)
Approx. cable overall diameter (mm)
Max. D.C resistance @ 20ºC (Ω/km)
4x1.5
RE or RM
0.8
1.8
11.0
12.1
4x2.5
RE or RM
0.8
1.8
11.9
7.41
4x4
RE or RM
1.0
1.8
14.0
4.61
4x6
RE or RM
1.0
1.8
15.3
3.08
4x10
RM
1.0
1.8
18.4
1.83
4x16
RM
1.0
1.8
20.9
1.15
4x25
SM
1.2
1.8
21.9
0.727
4x35
SM
1.2
1.8
24.1
0.524
4x50
SM
1.4
1.9
27.6
0.387
4x70
SM
1.4
2.1
31.4
0.268
4x95
SM
1.6
2.2
36.1
0.193
4x120
SM
1.6
2.3
39.3
0.153
4x150
SM
1.8
2.5
43.5
0.124
4x185
SM
2.0
2.7
48.4
0.0991
4x240
SM
2.2
2.9
54.6
0.0754
4x300
SM
2.4
3.1
60.4
0.0601
Send your message to this supplier